Regeneration Services
Many of our MicroTorr ambient temperature purifiers are regenerable. Regenerable means that the impurities inside the purifier are removed. Once a regeneration is performed on the purifier it has an identical lifetime as if it was a new purifier. The Regeneration process takes approximately 6-8 weeks from the day the purifier is received at the factory.
The Regeneration Process
Step 1: Is your purifier regenerable? Please consult the chart below to see if your purifier is regenerable. The media refers to the three digit number located in the part number of the purifier. For example the purifier MC1-902F contains 902 media which is regenerable.
Media example: MC3000-XXXF |
Is it Regenerable (Yes/No) |
Is it Dangerous Goods (Yes/No) |
202 |
Yes |
No |
203 |
Yes |
No |
206 |
Yes |
No |
302 |
No |
No |
402 |
No |
No |
403 |
No |
No |
404 |
Yes |
No |
502 |
No |
No |
602 |
No |
Yes [UN2881, Class 4.2] |
702 |
Yes |
Yes [UN3089, Class 4.1] |
703 |
Yes |
Yes [UN3089, Class 4.1] |
802 |
No |
Yes [UN3089, Class 4.1] |
804 |
Yes |
Yes [UN2881, Class 4.2] |
902 |
Yes |
Yes [UN2881, Class 4.2] |
903 |
Yes |
Yes [UN2881, Class 4.2] |
904 |
Yes |
Yes [UN2881, Class 4.2] |
905 |
Yes |
Yes [UN2881, Class 4.2] |
906 |
Yes |
No |
Step 2: Is your purifier classified as Dangerous Goods? Understanding if your purifier is Dangerous Goods (DG) is important because DG items must be shipped by someone certified to ship DG. This person will have attended classes on DG and has the relevant certification.
If the purifier is DG, please also provide the following information along with your request for an RMA#:
- Copy of Shipper’s Declaration of Dangerous Goods (REQUIRED for ALL Air and Ocean Shipments)
- Copy of DG Training Certificate for person signing Shipper’s Declaration of Dangerous Goods.
- Copy of Declaration of Contamination Form
Step 3: Fill out the RMA paperwork (click here) - All product returned to SAES Pure Gas requires a Return Material Authorization (RMA). All regenerations are processed through the customer service department at SAES Pure Gas. Please fill out the information located on this page of our website (click here). Please provide the information on that webpage and download the Declaration of Contamination form. Please contact our Customer Service Department if you have any questions:
SAES Pure Gas Field Service Engineers
- gp.fse@entegris.com
- International: +1 (805) 781-2392
- USA: 1 (800) 934-3628